Shunt Voltage Reference IC Adjustable 2.495V 36 VV ±1% 100 mA TO-92 (TO-226)

Quote
Alternative Part

Shunt Voltage Reference IC Adjustable 2.495V 36 VV ±0.5% 100 mA TO-92-3

Quote

Shunt Voltage Reference IC Adjustable 2.495V 36 VV ±1% 100 mA TO-92-3

Quote
1. TL431BILPE3 Substitution Conclusion The TL431BILPE3 is compatible with the original TL431ACLPG in core functionality (adjustable reference voltage of 2.495V–36V, 100mA output current) and package (TO-92-3). However, key differences include its higher accuracy (±0.5% vs. ±1%) and lower cathode operating current (700µA vs. 1mA). The improved accuracy benefits system voltage reference precision, while the lower cathode current may reduce power dissipation. It should be noted, however, that if the circuit was designed around the original part’s 1mA minimum cathode current, substitution could lead to instability under low‑current conditions—such as reference voltage drift or oscillation. Additionally, the TL431BILPE3 does not specify a temperature coefficient; if the application is sensitive to temperature drift, full‑temperature‑range performance should be verified. In summary, direct substitution is suitable in circuits where accuracy is critical and the cathode current meets the new requirement, but careful validation is recommended in dynamic‑load or low‑current scenarios.
2. TL431ACLPRAG Substitution Conclusion The TL431ACLPRAG, like the original TL431ACLPG, is manufactured by onsemi. Both share identical electrical parameters—including accuracy (±1%), typical temperature drift (50ppm/°C), and cathode current (1mA)—and use the same TO-92-3 package. The only distinction is that the TL431ACLPRAG features pre‑formed leads, typically intended for automated placement or specific soldering processes, whereas the original part has straight leads. For hand‑soldering or through‑hole applications, the lead form does not affect electrical performance, and the part can be substituted directly. If automated equipment is involved, however, compatibility between the formed‑lead dimensions and the equipment fixtures should be confirmed. In short, there is no electrical difference; only the mechanical form needs evaluation based on the production process.
Analysis ID: E729-1883000
Based on part parameters and for reference only. Not to be used for procurement or production.
SkyChip © 2026, Email: sales@skychip.com